3 thoughts on “OMRON Proper Installation of Rope or Wire Pull Emergency Stop Devices

  1. Been using the OMRON ER1022 Double Ended Pull Cable for about 10 years now (I think they have been around for at least 20+ years). Any idea why these double ended ones seem to be going away? Omron is quot­ing 10 week deliv­ery. A simil­i­ar (exact one maybe) by ABB Jokab seems to be a long lead time / non-return­able as well. Is it a spec change maybe? I like the one with the loc­al indic­at­ing light(s) and extra N/C con­tacts, because I have a require­ment to wire to 2 sep­ar­ate sys­tems.

    1. Hi D Hill,

      I’m sorry, but I don’t have any inside inform­a­tion about decisions like this made by indi­vidu­al man­u­fac­tur­ers. I can say that there are no tech­nic­al reas­ons that I am aware of that would obsol­ete these designs, so you should be able to obtain tech­nic­ally equi­val­ent devices from oth­er man­u­fac­tur­ers. I’m sorry I can­’t be more help on this one. 🙁