Canada

ISO 13849 – 1 Analysis — Part 7: Safety-Related Software

Posted on
General architecture model of software
This entry is part 7 of 9 in the series How to do a 13849 – 1 ana­lys­is

Safety-Related Soft­ware Up to this point, I have been dis­cuss­ing the basic pro­cesses used for the design of safety-related parts of con­trol sys­tems. The under­ly­ing assump­tion is that these tech­niques apply to the design of hard­ware used for safety pur­poses. The remain­ing ques­tion focuses on the design and devel­op­ment of safety-related soft­ware that runs on that […]

Canada

ISO 13849 – 1 Analysis — Part 6: CCF — Common Cause Failures

Posted on
This entry is part 6 of 9 in the series How to do a 13849 – 1 ana­lys­is

What is a Com­mon Cause Fail­ure? There are two sim­il­ar-sound­ing terms that people often get con­fused: Com­mon Cause Fail­ure (CCF) and Com­mon Mode Fail­ure. While these two types of fail­ures sound sim­il­ar, they are dif­fer­ent. A Com­mon Cause Fail­ure is a fail­ure in a sys­tem where two or more por­tions of the sys­tem fail at the same time from a single […]

Canada

ISO 13849 – 1 Analysis — Part 4: MTTFD – Mean Time to Dangerous Failure

Posted on
This entry is part 4 of 9 in the series How to do a 13849 – 1 ana­lys­is

Func­tion­al safety is all about the like­li­hood of a safety sys­tem fail­ing to oper­ate when you need it. Under­stand­ing Mean Time to Dan­ger­ous Fail­ure, or MTTFD, is crit­ic­al. If you have been read­ing about this top­ic at all, you may notice that I am abbre­vi­at­ing Mean Time to Dan­ger­ous Fail­ure with all cap­it­al let­ters. Using MTTFD is […]